General InformationRefrigerant Circuit with Expansion Valve and Evaporator
1 -
Evaporator
2 -
Expansion Valve
3 -
Valve for extracting, filling and measuring
4 -
Receiver/dryer with dryer bag/dryer cartridge
...
Test Requirements
Note
The A/C system is functioning correctly when the air flowing
from the instrument panel vents has a temperature of 70C
or lower.
Setting on Climatronic “LO”.
Setting on A/C system ...
Wire Break with Single Repair Point
Repair point with single crimp connection
–
Free up wire intended for repair (approximately 20 cm to
both sides of repair point).
–
If required, remove wiring harness wrapping using a folding
...