Volkswagen Polo Service & Repair Manual: Ultrasound A/C Cleaner -VAS6189B
| The Ultrasonic HVAC Cleaning System -VAS6189A- is placed in
the front passenger footwell and sprays Aero-Clean. Aero-Clean
neutralizes microbes and bacteria inside the heater and A/C
unit. |
| The unit comes with Operating Instructions. |
|
Evaporator, Cleaning with Suction Feed Spray Gun -VAG1538- and Spray
Nozzle
| Spray off the evaporator directly with Contra Sept using a
spray nozzle (approximately 10 bar (145 psi)). Contra Sept
neutralizes microbes and bacteria directly on the evaporator. |
| To make it possible to access the evaporator, some prework
and different spray nozzles are needed, for example
VAG1538/5;VAG1538/6 orVAG1538/7. |
| A vehicle-specific instruction booklet is included with the
evaporator cleaning solution D 600 100 A2 |
|
Fishy smell
–
From leak at cooling system of engine or of A/C system
heater core.
Note
...
Turn off the ignition.
–
Connect the A/C service station to the power supply.
–
Connect qui ...
Other materials:
How to start the engine using jump leads
Fig. 191 How to connect the jump
leads when starting vehicles without start/stop system: discharged battery â’¶ and
battery providing assistance â’·
Fig. 192 How to connect the jump
leads when starting vehicles with start/stop system: discharged battery â’¶ and
battery providing assistance ...
General Information
Perform a road test to determine if a vehicle pulls to one
side and if so, when and to which side. If the vehicle pulls to
one side. Refer to
→ Chapter „Corrective Action When Vehicle Pulls to One Side“.
If the vehicle ali ...
Indicator lamps and fuel gauge
Fig. 129 In the instrument cluster: Variants
A and B: fuel gauges for petrol and diesel. Variant C: fuel gauge for autogas
First read and observe the introductory information
and safety warnings 
Lit up
Needle position 
Possible cause †...
© 2016-2026 Copyright www.vwpolo.net