VW Polo manuals

Volkswagen Polo Service & Repair Manual: Ultrasound A/C Cleaner -VAS6189B

The Ultrasonic HVAC Cleaning System -VAS6189A- is placed in the front passenger footwell and sprays Aero-Clean. Aero-Clean neutralizes microbes and bacteria inside the heater and A/C unit.
The unit comes with Operating Instructions.

Evaporator, Cleaning with Suction Feed Spray Gun -VAG1538- and Spray Nozzle

Spray off the evaporator directly with Contra Sept using a spray nozzle (approximately 10 bar (145 psi)). Contra Sept neutralizes microbes and bacteria directly on the evaporator.
To make it possible to access the evaporator, some prework and different spray nozzles are needed, for example VAG1538/5;VAG1538/6 orVAG1538/7.
A vehicle-specific instruction booklet is included with the evaporator cleaning solution D 600 100 A2
Odor from Evaporator or Heat Exchanger?
  Fishy smell –  From leak at cooling system of engine or of A/C system heater core.   Note ...

Connecting Service Station
  Turn off the ignition. –  Connect the A/C service station to the power supply. –  Connect qui ...

Other materials:

Warning and indicator lamps
The warning and indicator lamps indicate various warnings , faults or certain functions. Some warning and indicator lamps light up when the ignition is switched on and should go out once the engine is running or the vehicle is in motion. Depending on the vehicle's equipment level, additional ...

Belt height adjuster
Fig. 54 Next to the front seats: belt height adjuster First read and observe the introductory information and safety warnings The seat belt height adjusters for the front seats can be used to adjust the position of the seat belt on the shoulder so that it can be fastened properly: Pus ...

Refrigerant in A/C Service station Container, Filling
  Caution If it is suspected that chemicals were added to the refrigerant circuit to seal leaks, do not connect the A/C service station and do not extract the refrigerant. ...