VW Polo manuals

Volkswagen Polo Service & Repair Manual: Support Mode with Battery Charger -VAS5095A

General Information
The support mode provides the vehicle electrical system with voltage when the battery is removed or disconnected.
For more information. Refer to Battery Charger -VAS5095A- Operating Instructions.
The support mode is used for the following situations
Vehicle electrical system support mode with the battery not installed
Maintaining the voltage when the battery is being replaced
Testing without the battery
  WARNING
Risk of injury. Follow all Warnings and Safety Precautions. Refer to → Chapter „Warnings and Safety Precautions“.
  WARNING
Batteries that have a light yellow visual indicator do not have to be tested or charged. Jump starting must not be used!
There is a risk of explosion during testing, charging or jump starting.
These batteries must be replaced.
–  Turn off the ignition and all electrical consumers.
  Caution
The polarity protection of the charger clamps is not active in the operation mode “charging severely discharged batteries/Support mode”. Connect the charger clamps to the battery terminals correctly according to polarity!
It can result in sparks due to short circuit.
This constitutes an explosion risk.
Make sure the charger clamps are secure.
Do not touch START/STOP when battery cables are incorrectly connected! The charger can be damaged.
–  Remove the battery.
  Caution
Whenever the battery is removed, be careful to prevent contact between the connected charge clamp on the positive terminal and the body ground. Likewise prevent contact between the battery terminals.
–  Connect the red charging clamp “+” to the vehicle positive terminal.
  Note
In the case of vehicles with a start/stop function and an installed Battery Monitoring Control Module -J367-, the black charging clamp “-” must be connected to the body ground. The start/stop system will malfunction if it is connected to the negative terminal on the battery.
–  Connect the black charging clamp “+” to the vehicle negative terminal.
–  Check the battery type setting on the battery type selector normal mode/support mode. Refer to → Chapter „Battery Charger -VAS5095A- Device Description“. Support mode must be on.
–  Verify that the charger clamps are connected to the correct polarity.
–  Switch on charging unit.
The charger begins the support mode.
End Battery Support Mode
–  Turn off the charger.
–  Remove the black charging clamp “-” of the charger from the negative battery terminal of the vehicle.
–  Remove the red charging clamp “+” of the charger from the positive battery terminal of the vehicle.
–  Pull out the electrical system connector of the charger.
   
Severely Discharged Battery, Charging with Battery Charger -VAS5095A
  WARNING Risk of injury. Follow all Warnings and Safety Precautions. Refer to → Chapter „Warnings and ...

Battery Charger -VAS5095A- Maintenance Charging
  WARNING Risk of injury. Follow all Warnings and Safety Precautions. Refer to → Chapter „Warnings and ...

Other materials:

Refrigerant Circuit with Expansion Valve and Evaporator
1 -  Evaporator 2 -  Expansion Valve 3 -  Valve for extracting, filling and measuring 4 -  Receiver/dryer with dryer bag/dryer cartridge ...

Refrigerant in A/C Service station Container, Filling
  Caution If it is suspected that chemicals were added to the refrigerant circuit to seal leaks, do not connect the A/C service station and do not extract the refrigerant. ...

Battery with Visual Indicator, Enhanced
This is a maintenance-free battery with liquid electrolyte (wet battery).   Caution Do not remove any of the labels on the battery and do not add distilled water. Only perform a visual ...

© 2016-2024 Copyright www.vwpolo.net