Volkswagen Polo Service & Repair Manual: Service Test, Performing
Note
| The printed test results can differ depending on the
software version. |
| Read the Battery Tester -VAS6161- Operating Instructions. |
WARNING
| Do not check or charge batteries that have a visual
indicator that is bright yellow. Jump starting must not
be used! |
| There is a risk of explosion during testing,
charging or jump starting. |
| These batteries must be replaced. |
|
| – |
Select “at the battery pole” or “at the battery jump start
terminal”. |
| – |
Select the type of battery: “standard”, “AGM”, “2*6V” or
“Gel”. |
| – |
Select the “CCA”, “JIS”, “DIN”, “SAE”, “IEC” or “EN”. |
| – |
Measure the temperature. Hold the temperature sensor
approximately 5 cm above the battery pole until the temperature
is stable. |
| – |
Print out the test report if necessary. |
|
|
|
WARNING
Do not check or charge batteries that have a visual
indicator that is bright yellow. Jump starting must not
...
1 -
Type of test.
2 -
Battery test result.
3 -
Measured voltage
...
Other materials:
Special Tools
Special tools and workshop equipment
required
Suction Feed Spray Gun -VAG1538-
Stone Chip Tester -VAS5102A-
Paint Thickness Test -VAS5278-
Paint Thickness T ...
12 V Socket
12 V Socket , Removing and Installing
Caution
Using force to remove cigarette lighter sockets
without illumination can result in damage to the
mounting sleeve retainers.
The Cigare ...
Maintenance Test, Performing
WARNING
Do not check or charge batteries that have a visual
indicator that is bright yellow. Jump starting must not
be used!
There is a risk of explosion during testing,
cha ...