VW Polo manuals

Volkswagen Polo Service & Repair Manual: Service Test, Performing

  Note
The printed test results can differ depending on the software version.
Read the Battery Tester -VAS6161- Operating Instructions.
  WARNING
Do not check or charge batteries that have a visual indicator that is bright yellow. Jump starting must not be used!
There is a risk of explosion during testing, charging or jump starting.
These batteries must be replaced.
–  Select “Service Test”.
–  Select “at the battery pole” or “at the battery jump start terminal”.
–  Select the type of battery: “standard”, “AGM”, “2*6V” or “Gel”.
–  Select the “CCA”, “JIS”, “DIN”, “SAE”, “IEC” or “EN”.
–  Select battery value.
–  Measure the temperature. Hold the temperature sensor approximately 5 cm above the battery pole until the temperature is stable.
–  Start the test.
–  Print out the test report if necessary.
   
Maintenance Test, Performing
  WARNING Do not check or charge batteries that have a visual indicator that is bright yellow. Jump starting must not ...

Explanation of Test Results
1 -  Type of test. 2 -  Battery test result. 3 -  Measured voltage ...

Other materials:

Pressure and Boiling Point
The boiling point given in tables for a liquid is always referenced to an atmospheric pressure of 1 bar (14.5 psi). If the pressure acting on a fluid changes, its boiling point also changes. For example, water boils at a lower temperatur ...

Changing a blown fuse
Fig. 174 A blown fuse Fig. 175 Removing or fitting a fuse using the plastic pliers ① First read and observe the introductory information and safety warnings Preparation Switch off the ignition, the lights and all electrical consumers. Open the appropriate fuse box . Detecti ...

Primary Lock
The primary lock is the locking mechanism of an individual crimp contact in the contact housing. If necessary, housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing the contacts. ...

© 2016-2026 Copyright www.vwpolo.net