VW Polo manuals

Volkswagen Polo Service & Repair Manual: Service Test, Performing

  Note
The printed test results can differ depending on the software version.
Read the Battery Tester -VAS6161- Operating Instructions.
  WARNING
Do not check or charge batteries that have a visual indicator that is bright yellow. Jump starting must not be used!
There is a risk of explosion during testing, charging or jump starting.
These batteries must be replaced.
–  Select “Service Test”.
–  Select “at the battery pole” or “at the battery jump start terminal”.
–  Select the type of battery: “standard”, “AGM”, “2*6V” or “Gel”.
–  Select the “CCA”, “JIS”, “DIN”, “SAE”, “IEC” or “EN”.
–  Select battery value.
–  Measure the temperature. Hold the temperature sensor approximately 5 cm above the battery pole until the temperature is stable.
–  Start the test.
–  Print out the test report if necessary.
   
Maintenance Test, Performing
  WARNING Do not check or charge batteries that have a visual indicator that is bright yellow. Jump starting must not ...

Explanation of Test Results
1 -  Type of test. 2 -  Battery test result. 3 -  Measured voltage ...

Other materials:

AGM Battery, Checking
Perform Battery Checks in the Following Sequence: 1.  Visual inspection. Refer to → Chapter „Visual Inspection“. 2.  Check the battery using the Battery Tester -VAS6161-. Refer to ...

Run-Flat Tire, Structure and Identification, SST Tire
Run-Flat Tires, Dismounting and Mounting. Refer to → Chapter „Tires, Mounting“. A Tire Pressure Monitoring Display is Necessary When Using Run-Flat Tires. Tire Damage and the Pressure Loss Resulting From it ...

Retrofitting a towing bracket
Fig. 92 Dimensions and attachment points for retrofitting a towing bracket First read and observe the introductory information and safety warnings Volkswagen recommends having the towing bracket retrofitted by a qualified workshop. The cooling system may need to be modified or heat shields ...