VW Polo manuals

Volkswagen Polo Service & Repair Manual: Extraction and Charging System Safety Regulations

Make sure the shut-off valves are closed before connecting the charging system to the air conditioning system.
Make sure the process is finished before disconnecting the charging system from the A/C system. This prevents any refrigerant from escaping into the atmosphere.
Once the purified refrigerant from the charging system has been transferred to an external compressed-gas cylinder, close the hand shut-off valves at the cylinder and charging system.
Do not expose charging system to moisture or use it in a wet environment.
Disconnect from power supply before performing service work on the charging system.
Never use an extension cable on account of the fire hazard. If the use of an extension cable is unavoidable, the minimum cross-section should be 2.5 mm2.
In case of fire, remove the external cylinder.
Entrained oil from the air conditioning system drawn by the suction unit into the measurement vessel supplied is subsequently to be transferred to a sealed container as it contains a small quantity of refrigerant. It must not be released into the environment.
Following shutdown, A/C service station is to be secured to stop it rolling away.
   
Handling Pressure Vessels
Secure vessels to prevent them falling over! Secure upright cylinders to stop them falling over and cylinders lying flat to stop them rolling away. ...

A/C System and Refrigerant R134a Safety Precautions
A/C Service Station -VAS6007A- (and further or current A/C Service Station) Refer to the Workshop Equipment Catalog. ...

Other materials:

Checklist
To ensure your own safety and that of your passengers, observe the following actions in the specified order : Stop the vehicle at a safe distance away from moving traffic and on a suitable surface . Switch on the hazard warning lights using the button . Apply the handbrake ...

Evaporator Vent Temperature Sensor -G263- or Evaporator Temperature Sensor -G308
Function: The Evaporator Vent Temperature Sensor -G263- or Evaporator Temperature Sensor -G308- determines the temperature behind the evaporator. This value goes to the air conditioning control module and serves as a reference signal for ...

Refrigerant Circuit, Tracing Leaks, with Leak Detection System -VAS6196- or Leak Detection Kit -VAS6201A- or Succeeding Model
  Note This repair manual describes different methods for detecting leaks in the refrigerant circuit. These methods have been tested and result in success when used correctly. If when searching for compressed air / Nit ...