Volkswagen Polo Service & Repair Manual: Battery Charger -VAS5900- Maintenance Charging
Note
| If the battery is discharged by an electrical consumer
during maintenance charging, the Battery Charger -VAS5900-
automatically supplies the appropriate charge. |
| Maintenance charging can be performed without time
restrictions. |
| The battery can be used constantly. |
| Observe the maintenance notes of the battery manufacturer. |
WARNING
| Risk of injury. Follow all Warnings and Safety
Precautions. Refer to
→ Chapter „Warnings and Safety Precautions“. |
|
WARNING
| Batteries that have a light yellow visual indicator
do not have to be tested or charged. Jump starting must
not be used! |
| There is a risk of explosion during testing,
charging or jump starting. |
| These batteries must be replaced. |
|
| If the battery is fully charged, the Battery Charger
-VAS5900- starts maintenance charging. |
| – |
Proceed as when charging the battery. Refer to
→ Chapter „Battery, Charging with Battery Charger -VAS5900-“. |
|
|
|
| With a charge status of 100%, all bars are indicated on the
display. |
|
|
|
General Information
The support mode provides the vehicle electrical system with
voltage when the battery is removed or disconnected.
...
Other materials:
Refrigerant Circuit with A/C Service Station, Draining
Caution
If it is suspected that chemicals were added to the
refrigerant circuit to seal leaks, do not connect the
A/C service station and do not extract the refrigerant.
...
Wire Break with Dual Repair Point
Repair point with intermediate wire section
–
Free up wire intended for repair at two points
(approximately 20 cm to both sides of respective repair points).
–
If required, remove wiring harness wra ...
Legal Requirements
The manufacturer is granted general type approval for the
whole vehicle including all parts and for specific retrofitting
(general type approval according to § 20 StVZO (Motor Vehicle
Construction and Use Regulations or EU type approval).
...