Volkswagen Polo Service & Repair Manual: Battery Charger -VAS5095A- Maintenance Charging
WARNING
| Risk of injury. Follow all Warnings and Safety
Precautions. Refer to
→ Chapter „Warnings and Safety Precautions“. |
|
WARNING
| Batteries that have a light yellow visual indicator
do not have to be tested or charged. Jump starting must
not be used! |
| There is a risk of explosion during testing,
charging or jump starting. |
| These batteries must be replaced. |
|
| During maintenance charging, the Battery Charger -VAS5095A-
provides safe charging and preserves the charge of the battery. |
| – |
Proceed as when charging the battery. Refer to
→ Chapter „Battery, Charging with Battery Charger -VAS5095A-“. |
Note
| If the battery is discharged by an electrical consumer
during maintenance charging, the Battery Charger -VAS5095A-
automatically supplies the appropriate charge. |
| Maintenance charging can be performed without time
restrictions. |
| The battery can be used constantly. |
|
General Information
The support mode provides the vehicle electrical system with
voltage when the battery is removed or disconnected.
...
Other materials:
Test Requirements
Note
The A/C system is functioning correctly when the air flowing
from the instrument panel vents has a temperature of 70C
or lower.
Setting on Climatronic “LO”.
Setting on A/C system ...
AGM Battery
Maintenance-Free Battery with Specific Electrolyte without a
Visual Indicator
Lead-acid battery, where the electrolyte is fixed in an
absorbent glass mat (AGM). The battery is closed and equipped
with breather valves.
...
Matting Component -ALN 775 106
Definition:
Matting Component -ALN 775 106-
Edition 04/2013
Product Description
With the two-part HS top coat, the Matting Component -ALN
775 106- produce a matted top coat c ...