Volkswagen Polo Service & Repair Manual: Refrigerant Still in Circuit
| Discharge the refrigerant circuit. |
| – |
Remove malfunctioning component, flush with compressed air,
collect escaping refrigerant oil. |
| – |
The new component is to be filled with the amount of
refrigerant oil flushed out (plus 20 cm3
for evaporator, plus 10 cm3 for
condenser, refrigerant pipes and refrigerant hoses) as fresh
refrigerant oil fill. |
| – |
Replace the restrictor depending on the vehicle. |
| – |
Assemble, evacuate and charge the refrigerant circuit. |
|
–
Remove malfunctioning component.
–
Remove the A/C compressor.
–
Remove oil drain plug fr ...