Volkswagen Polo Service & Repair Manual: Midtronics Battery Tester -MCR340VKT-, Troubleshooting
| Sometimes the display shows the malfunction or the messages
based on the condition. |
| The following is a list of the most frequent displayed
messages together with suggested solutions. |
Note
| Refer to the MCR340V Operating Instructions for messages not
listed here. |
|
|
|
| Display Message |
Measure |
| No display |
| – |
Make sure the battery tester terminals are attached securely
to the battery terminals. |
| – |
Make sure the battery pole is tightened to the tightening
specification and is not corroded. |
| – |
Charge battery. Refer to
→ Chapter „Battery Tester Charger Kit -GRX3000VAS-“. |
|
| System noises |
| – |
Switch off all electrical consumers. |
| – |
Wait until all electrical equipment, which are monitored by
the vehicle electrical system control module, are switched off.
|
| – |
Disconnect any doubtful or standard production electrical
equipment from the vehicle electrical system. |
|
| Wait a few minutes and then perform the test again. Refer to
→ Chapter „Battery, Testing using Midtronics Battery Tester
-MCR340VKT-“. |
Note
| If the test was performed at the battery jump start terminal
and the message still does not go away, then perform the test
directly on the battery. |
|
Requirements
WARNING
Read and follow the Safety Precautions when working
with batteries. Refer to
...
WARNING
Batteries that have a light yellow visual indicator
do not have to be tested or charged. Jump starting must
...
Other materials:
Various securing systems
Fig. 62 On the rear seats: figure Ⓐ illustrates
the main securing points for the child restraint system on the lower retaining rings
and top tether. Figure Ⓑ shows how to secure a child restraint system using the
vehicle's seat belt
First read and observe the introductory information
a ...
Refrigerant R134a Vapor Pressure Table
The vapor pressure table for every refrigerant is published
in literature for refrigeration system engineers. This table
makes it possible to determine the vapor pressure acting on the
column of liquid in a vessel if the temperature of the vessel is
know ...
Test Requirements
Radiator and condenser are clean (clean if necessary).
The ribbed belt for the A/C compressor and alternator
tensioned correctly.
All air ducts, covers and seals are OK and installed
correctly.
...