Volkswagen Polo Service & Repair Manual: Midtronics Battery Tester -MCR340VKT-, Troubleshooting
| Sometimes the display shows the malfunction or the messages
based on the condition. |
| The following is a list of the most frequent displayed
messages together with suggested solutions. |
Note
| Refer to the MCR340V Operating Instructions for messages not
listed here. |
|
|
|
| Display Message |
Measure |
| No display |
| – |
Make sure the battery tester terminals are attached securely
to the battery terminals. |
| – |
Make sure the battery pole is tightened to the tightening
specification and is not corroded. |
| – |
Charge battery. Refer to
→ Chapter „Battery Tester Charger Kit -GRX3000VAS-“. |
|
| System noises |
| – |
Switch off all electrical consumers. |
| – |
Wait until all electrical equipment, which are monitored by
the vehicle electrical system control module, are switched off.
|
| – |
Disconnect any doubtful or standard production electrical
equipment from the vehicle electrical system. |
|
| Wait a few minutes and then perform the test again. Refer to
→ Chapter „Battery, Testing using Midtronics Battery Tester
-MCR340VKT-“. |
Note
| If the test was performed at the battery jump start terminal
and the message still does not go away, then perform the test
directly on the battery. |
|
Requirements
WARNING
Read and follow the Safety Precautions when working
with batteries. Refer to
...
WARNING
Batteries that have a light yellow visual indicator
do not have to be tested or charged. Jump starting must
...
Other materials:
Charging, replacing, disconnecting and connecting the vehicle battery
First read and observe the introductory information
and safety warningsCharging the battery
The vehicle battery should be charged by a qualified workshop, as the technology
used in factory-fitted batteries requires voltage-limited charging . Volkswagen
recommends using a Volkswagen dealership ...
Refrigerant Circuit, Tracing Leaks, with Electronic Leak Detector -VAG1796
Note
This repair manual describes different methods for detecting
leaks in the refrigerant circuit. These methods have been tested
and result in success when used correctly.
If when searching for compressed air / Nit ...
Charge Factor
A vessel must have space for vapor as well as liquid. As the
temperature rises, the liquid expands. The space filled with
vapor decreases. At a certain point, there will only be liquid
in the vessel. Beyond this, even a slight increase in
temperature cau ...
© 2016-2026 Copyright www.vwpolo.net