Volkswagen Polo Service & Repair Manual: Test Requirements
Note
| The A/C system is functioning correctly when the air flowing
from the instrument panel vents has a temperature of 70C
or lower. |
| Setting on Climatronic “LO”. |
| Setting on A/C system “AC” on; “max”; “cold”. |
| The A/C system OBD cannot find malfunctions with the Vehicle
Diagnostic Tester in “Guided Fault Finding”. The measured value
block does not show any shut-off condition for the A/C
compressor (only on vehicles with “A/C system” OBD). |
|
|
|
Note
The A/C system is functioning correctly when the air flowing
from the instrument panel vents has a temperature of 70C
or lower.
...
Other materials:
Spray Can Filling Device -VAS6425
Definition:
Spray Can Filling Device -VAS6425-
Product Description
The spray can filling device is a pneumatic,
maintenance-free dispensing device for filling spray cans with
mixed base paint ...
A/C Programmer -J127
This programmer switches the refrigerant flow direction
through the second evaporator if the temperature on the cooling
fins on the second evaporator lowers to the freezing point for
water (icing protection).
...
Evaporator Vent Temperature Sensor -G263- or Evaporator Temperature Sensor
-G308
Function:
The Evaporator Vent Temperature Sensor -G263- or Evaporator
Temperature Sensor -G308- determines the temperature behind the
evaporator. This value goes to the air conditioning control
module and serves as a reference signal for ...