Volkswagen Polo Service & Repair Manual: Restrictor
Caution
| Non-approved tools or materials such as leak sealing
additives can cause damage or malfunctions in the
system. |
| Only use tools and materials approved by the
manufacturer. |
| The warranty is voided if non-approved tools or
materials are used. |
|
| All components of the refrigerant circuit submitted for
quality observation are always to be sealed (use original
sealing caps of original part). |
| Replace damaged or leaking components of refrigerant
circuit. Refer to
→ Chapter „Components, Replacing“. |
| To date, the original parts (compressor, reservoir,
receiver/dryer, evaporator and condenser) have been filled with
nitrogen gas. This charge is being gradually discontinued. There
is little or no pressure equalization when removing the sealing
plugs from the original part. |
|
|
|
| The restrictor creates a constriction. This restriction
reduces the flow and creates high and low pressure sides in the
refrigerant circuit. Before the restrictor the refrigerant which
is under a higher pressure is warm. After the restrictor the
refrigerant which is under a low pressure is cold. Before the
restriction there is a strainer for contaminants and after the
restriction there is a strainer, to atomize the refrigerant
before it reaches the evaporator. |
Note
| Arrow -A- on restrictor points
to evaporator. |
| Replace after each opening of the circuit. |
| Refer to the Parts Catalog. |
|
|
|
Caution
Non-approved tools or materials such as leak sealing
additives can cause damage or malfunctions in the
sys ...
Caution
Non-approved tools or materials such as leak sealing
additives can cause damage or malfunctions in the
sys ...
Other materials:
Improvised Tools
Note
This list outlines the testers, tools and materials required
for expert refrigerant circuit repair work.
Caution
Non-approved tools or materials such as leak sealing
additiv ...
Side airbags
Fig. 59 On left-hand side of vehicle:
deployment zone of the side airbag (variant A). On the side of the front seat: location
and deployment range of the side airbag (variant B)
First read and observe the introductory information
and safety warnings
The side airbags are located in the outer ...
Refrigerant R134a Vapor Pressure Table
The vapor pressure table for every refrigerant is published
in literature for refrigeration system engineers. This table
makes it possible to determine the vapor pressure acting on the
column of liquid in a vessel if the temperature of the vessel is
know ...