Volkswagen Polo Service & Repair Manual: O-Ring
Caution
| Non-approved tools or materials such as leak sealing
additives can cause damage or malfunctions in the
system. |
| Only use tools and materials approved by the
manufacturer. |
| The warranty is voided if non-approved tools or
materials are used. |
|
| All components of the refrigerant circuit submitted for
quality observation are always to be sealed (use original
sealing caps of original part). |
| Replace damaged or leaking components of refrigerant
circuit. Refer to
→ Chapter „Components, Replacing“. |
| To date, the original parts (compressor, reservoir,
receiver/dryer, evaporator and condenser) have been filled with
nitrogen gas. This charge is being gradually discontinued. There
is little or no pressure equalization when removing the sealing
plugs from the original part. |
|
|
|
| These o-rings seal off the connection points between
individual components of the refrigerant circuit. |
| Only O-rings that are resistant to refrigerant r134a and
refrigerant oil must be installed. Make sure they are original
replacement parts. |
| Refer to the Parts Catalog. |
| Make sure diameters -a- and
-b- are correct. |
| Coat with refrigerant oil before installing |
Note
| The color coding of refrigerant circuit o-rings with R134a
has been discontinued. Colored and black O-rings are used. |
| Refer to the Parts Catalog. |
|
|
|
Caution
Non-approved tools or materials such as leak sealing
additives can cause damage or malfunctions in the
sys ...
Caution
Non-approved tools or materials such as leak sealing
additives can cause damage or malfunctions in the
sys ...
Other materials:
Coolant specification
First read and observe the introductory information
and safety warningsThe cooling system is filled at the factory with a mixture
of specially prepared water and at least 40% coolant additive G 13
(TL-VW 774 J). The coolant additive is dyed purple. This mixture of water and coolant
additive ...
Secondary Lock
The secondary lock is a housing securing mechanism (second
locking mechanism) that secures all wires in one contact
housing. If a secondary lock is installed at a contact housing,
it must always be opened or removed using specified tool before
releasing ...
Commercial Names and Designations
Refrigerant R134a is currently available under the following
trade names:
H-FKW 134a
SUVA 134a
KLEA 134a
Note
Different trade names may be us ...