VW Polo manuals

Volkswagen Polo Service & Repair Manual: Extraction and Charging System Safety Regulations

Make sure the shut-off valves are closed before connecting the charging system to the air conditioning system.
Make sure the process is finished before disconnecting the charging system from the A/C system. This prevents any refrigerant from escaping into the atmosphere.
Once the purified refrigerant from the charging system has been transferred to an external compressed-gas cylinder, close the hand shut-off valves at the cylinder and charging system.
Do not expose charging system to moisture or use it in a wet environment.
Disconnect from power supply before performing service work on the charging system.
Never use an extension cable on account of the fire hazard. If the use of an extension cable is unavoidable, the minimum cross-section should be 2.5 mm2.
In case of fire, remove the external cylinder.
Entrained oil from the air conditioning system drawn by the suction unit into the measurement vessel supplied is subsequently to be transferred to a sealed container as it contains a small quantity of refrigerant. It must not be released into the environment.
Following shutdown, A/C service station is to be secured to stop it rolling away.
   
Handling Pressure Vessels
Secure vessels to prevent them falling over! Secure upright cylinders to stop them falling over and cylinders lying flat to stop them rolling away. ...

A/C System and Refrigerant R134a Safety Precautions
A/C Service Station -VAS6007A- (and further or current A/C Service Station) Refer to the Workshop Equipment Catalog. ...

Other materials:

Searching for Refrigerant Circuit Leaks with Compressed Air or Nitrogen
  Note This repair manual describes different methods for detecting leaks in the refrigerant circuit. These methods have been tested and result in success when used correctly. If when searching for compressed air / Nit ...

Positive and earth jump lead connection points
Fig. 190 In the engine compartment: jump lead connection point, positive ⊕ First read and observe the introductory information and safety warnings The positive jump lead connection point is in the engine compartment. In order to establish a suitable earth connection, screw towing eye into ...

Refrigerant Circuit
A/C System Repair Information An A/C system made for refrigerant R12 must not be filled with refrigerant R134a without making modifications to the refrigerant circuit. Refer to → Chapter „Refrigerant Circuit, Converting R12 to R134a and Ser ...