VW Polo manuals

Volkswagen Polo Service & Repair Manual: Extraction and Charging System Safety Regulations

Make sure the shut-off valves are closed before connecting the charging system to the air conditioning system.
Make sure the process is finished before disconnecting the charging system from the A/C system. This prevents any refrigerant from escaping into the atmosphere.
Once the purified refrigerant from the charging system has been transferred to an external compressed-gas cylinder, close the hand shut-off valves at the cylinder and charging system.
Do not expose charging system to moisture or use it in a wet environment.
Disconnect from power supply before performing service work on the charging system.
Never use an extension cable on account of the fire hazard. If the use of an extension cable is unavoidable, the minimum cross-section should be 2.5 mm2.
In case of fire, remove the external cylinder.
Entrained oil from the air conditioning system drawn by the suction unit into the measurement vessel supplied is subsequently to be transferred to a sealed container as it contains a small quantity of refrigerant. It must not be released into the environment.
Following shutdown, A/C service station is to be secured to stop it rolling away.
   
Handling Pressure Vessels
Secure vessels to prevent them falling over! Secure upright cylinders to stop them falling over and cylinders lying flat to stop them rolling away. ...

A/C System and Refrigerant R134a Safety Precautions
A/C Service Station -VAS6007A- (and further or current A/C Service Station) Refer to the Workshop Equipment Catalog. ...

Other materials:

Battery Tester Charger Kit -GRX3000VAS- General Description
Only Volkswagen approved chargers may be used to charge batteries in Volkswagen vehicles. Only the Battery Tester Charger Kit -GRX3000VAS- charger is used in the USA and Canada. The Battery Tester Charger Kit -GRX3000VAS- battery charger ...

Two-Part HS Vario Clear Coat
Definition: Two-Part HS Vario Clear Coat -L2K 769 K01 A5- Edition 06/2013 Product Description Two-part HS vario clear coat is a VOC compliant (VOC value less than 420 g/L), h ...

Magnetic Clutch High Pressure Switch -F118
  Note For switching pressures, removing and installing switches and switch arrangement and version, see vehicle-specific refrigerant circuit. Refer to → Rep. Gr.87.     ...