Volkswagen Polo Service & Repair Manual: Evacuating and Charging Valve with Schrader Valve
| Special tools and workshop equipment
required |
| Torque Wrench 1783 - 2-10Nm -VAG1783- with Torque Wrench
1783 - 1/4" Drive Ratchet -VAS6234- |
WARNING
| There is a danger of ice-up. |
| Refrigerant will leak out if refrigerant circuit is
not discharged. |
| Refrigerant must be extracted before opening
refrigerant circuit. If refrigerant circuit is not
opened within 10 minutes of extraction, pressure may
form in refrigerant circuit due to evaporation. Extract
the refrigerant once more. |
|
| Only valves and connections that are resistant to
refrigerant R134a and refrigerant oil must be installed. |
| Different connections (outer diameter) for high pressure and
low pressure side. |
| Always screw on sealing caps. |
|
|
|
| Refer to
→ Rep. Gr.87 for the vehicle-specific repair manual. |
Note
| Torque Wrench 1783 - 2-10Nm -VAG1783- with Torque Wrench
1783 - 1/4" Drive Ratchet -VAS6234- |
| Use a suitable Refrigerant Sockets -T10364- to loosen the
Schrader valve insert. Refer to
→ Fig. „“ Refrigerant Sockets -T10364- for the high pressure/low
pressure side service connection valves in the refrigerant
circuit”“ |
| A - |
Service connection (soldered in) |
| B - |
Schrader valve insert (2.4 ± 0.2 Nm) |
| C - |
O-ring (belongs to the valve) |
| D - |
Sealing cap with seal |
|
|
|
Special tools and workshop equipment
required
Torque Wrench 1783 - 2-10Nm -VAG1783- with Torque Wrench
1783 - 1/4" Drive Ratchet -VA ...
Other materials:
Wear Spots
A wear spot is a flat spot on the tread of the tires that
can be caused by extreme braking maneuvers on subsurface such as
asphalt.
At the same time a tire during the braking maneuver is
rubbed at selective points which ...
Cigarette Lighter Socket, Removing and Installing
Special tools and workshop equipment
required
Cigarette Lighter Release Tool -T40148-
Note
The removal and installation for all sockets is performed in
the same way and is only described for the ciga ...
Discharge Refrigerant Circuit with A/C Service Station
Caution
If it is suspected that chemicals were added to the
refrigerant circuit to seal leaks, do not connect the
A/C service station and do not extract the refrigerant.
...