Volkswagen Polo Service & Repair Manual: Service Test, Performing
Note
| The printed test results can differ depending on the
software version. |
| Read the Battery Tester -VAS6161- Operating Instructions. |
WARNING
| Do not check or charge batteries that have a visual
indicator that is bright yellow. Jump starting must not
be used! |
| There is a risk of explosion during testing,
charging or jump starting. |
| These batteries must be replaced. |
|
| – |
Select “at the battery pole” or “at the battery jump start
terminal”. |
| – |
Select the type of battery: “standard”, “AGM”, “2*6V” or
“Gel”. |
| – |
Select the “CCA”, “JIS”, “DIN”, “SAE”, “IEC” or “EN”. |
| – |
Measure the temperature. Hold the temperature sensor
approximately 5 cm above the battery pole until the temperature
is stable. |
| – |
Print out the test report if necessary. |
|
|
|
WARNING
Do not check or charge batteries that have a visual
indicator that is bright yellow. Jump starting must not
...
1 -
Type of test.
2 -
Battery test result.
3 -
Measured voltage
...
Other materials:
Plastic Cleaner
Definition:
Plastic Cleaner -D 195 850 A1-
Edition 04/2009
Product Description
Plastic Cleaner -D 195 850 A1- is a liquid universal cleaner
and thinner with an non-aromatic, ...
Battery, Testing using Midtronics Battery Tester -MCR340VKT
Requirements
WARNING
Read and follow the Safety Precautions when working
with batteries. Refer to
→ Chapter „Warnings and Safety Precautions“.
...
Combined curtain and side airbags
Fig. 60 On left-hand side of vehicle:
deployment zone of the combined curtain and side airbags (variant A). On the side
of the front seat: location and deployment zone of the combined curtain and side
airbag (variant B)
First read and observe the introductory information
and safety warning ...