VW Polo manuals

Volkswagen Polo Service & Repair Manual: Service Test, Performing

  Note
The printed test results can differ depending on the software version.
Read the Battery Tester -VAS6161- Operating Instructions.
  WARNING
Do not check or charge batteries that have a visual indicator that is bright yellow. Jump starting must not be used!
There is a risk of explosion during testing, charging or jump starting.
These batteries must be replaced.
–  Select “Service Test”.
–  Select “at the battery pole” or “at the battery jump start terminal”.
–  Select the type of battery: “standard”, “AGM”, “2*6V” or “Gel”.
–  Select the “CCA”, “JIS”, “DIN”, “SAE”, “IEC” or “EN”.
–  Select battery value.
–  Measure the temperature. Hold the temperature sensor approximately 5 cm above the battery pole until the temperature is stable.
–  Start the test.
–  Print out the test report if necessary.
   
Maintenance Test, Performing
  WARNING Do not check or charge batteries that have a visual indicator that is bright yellow. Jump starting must not ...

Explanation of Test Results
1 -  Type of test. 2 -  Battery test result. 3 -  Measured voltage ...

Other materials:

Checking with Restrictor and Reservoir, with Internally Regulated A/C Compressor
  Note Connecting service station. Refer to → Chapter „Connecting Service Station“. Observe test requirements. Refer to → Chapter „Pressures, Checking“. –  ...

MFD (multifunction display) menu
First read and observe the introductory information and safety warnings The multifunction display (MFD) is equipped with two automatic memories: 1 - Trip memory and 2 - Total journey memory. The number of the current memory on display will be shown in the upper right-hand corner of the displ ...

Cavity Sealant
Definition: Cavity Sealant -D 330 KD1 A2- Cavity Sealant -D 330 KD2 A1- Edition 04/2010 Product Description Cavity Sealant -D 330 KD1 A2- and Cavity Se ...

© 2016-2026 Copyright www.vwpolo.net