  Note
Check cooling performance. The A/C system is functioning correctly when the air flowing from the instrument panel vents has a temperature of 70C or lower.
Setting on Climatronic “LO”.
Setting on A/C system “AC” on; “max”; “cold”.
Connections with valve and service connections for measuring and checking.
Check on vehicles with restrictor and reservoir (with internally regulated A/C compressor). Refer to → Chapter „Checking with Restrictor and Reservoir, with Internally Regulated A/C Compressor“.
Check on vehicles with expansion valve and receiver/dryer (with internally regulated A/C compressor). Refer to → Chapter „Checking with Expansion Valve and Receiver/Dryer, with Internally Regulated A/C Compressor“.
On vehicles with expansion valve and receiver/dryer (without regulated A/C compressor). Refer to → Chapter „Checking with Expansion Valve and Receiver/Dryer, without Regulated A/C Compressor“.
Checking pressures for vehicles with restrictor, reservoir and A/C Compressor Regulator Valve -N280- (externally regulated A/C compressor). Refer to → Chapter „Checking with Restrictor, Reservoir and A/C Compressor Regulator Valve -N280-, Externally Regulated A/C Compressor“.
   
Pressures, Checking
  Note Check cooling performance. The A/C system is functioning correctly when the air flowing from the instrument panel vents has a temperature of ...

Checking with Restrictor and Reservoir, with Internally Regulated A/C Compressor
  Note Connecting service station. Refer to → Chapter „Connecting Service Station“. Observe test requirements ...

Other materials:

Refrigerant, Keeping Records
  Note The laws and regulations listed below are applicable in Germany. Different or additional laws and regulations may apply in other countries. Addresses in other countries can be obtained from the relevant au ...

Refrigerant R134a Environmental Information
Vehicle air conditioning systems make use of the vaporization and condensation process. In this case, one works with a substance which boils easily, designated as refrigerant. The refrigerant employed is tetrafluoroethane R134a, which bo ...

Infrared Dryer -VAS6875
Definition: Infrared Dryer -VAS6875- Product Description: The infrared dryer is used to dry paste, filler, base paint, top coats and clear coats on vertical and horizontal surfaces using two ...